VE4020A1195T Thermal Actuator with Extended Range for Gas Control - View 1
Honeywell

VE4020A1195T Thermal Actuator with Extended Range for Gas Control

Thermal Actuator with Extended Range for Gas Control

Technical Specifications

ParameterSpecification
Product TypeSolenoid Gas Valve
SeriesVE4000
Nominal SizeDN20
FunctionON OFF, normally closed
Coil Voltage220–240 Vac
Max Operating Pressure360 mbar
Opening TimeLess than 1 second
Closing TimeLess than 1 second
Max Switching Frequency20 cycles per minute
Enclosure RatingIP65
Pressure TapsAuxiliary inlet pressure tap
FilterIntegrated fine mesh filter
ApplicationCommercial and industrial burner gas trains

Notes

Product Overview

VE4020A1195T is a DN20 normally closed solenoid gas valve designed for safety shut-off duty in burner gas trains.
It belongs to the VE4000A family, which focuses on fast and reliable ON OFF control without integrated flow regulation.

This model is typically installed as a main safety valve or secondary shut-off valve in commercial boilers, industrial burners, ovens, furnaces, and similar gas-fired equipment. Its fast closing response supports compliance with burner safety requirements during emergency shutdown or power loss.

Key Features

  • Normally closed, spring-loaded safety shut-off design
  • Fast opening and closing response to protect burners
  • DN20 body suitable for medium gas flow applications
  • Designed for continuous-duty operation within rated cycle limits
  • IP65 enclosure suitable for industrial environments
  • Integrated fine mesh filter to reduce contamination risk
  • Standardized VE4000 platform for easy replacement and service

Packaging & Delivery

  • Individual industrial carton packaging
  • Export packing available for international shipment
  • Suitable for spare parts stocking and retrofit projects

Frequently Asked Questions (FAQ)

Q: Is this valve pressure regulating?
A: No, VE4020A1195T is a pure ON OFF safety shut-off valve.

Q: Where is DN20 typically used?
A: DN20 is common in medium-capacity burner gas trains and commercial heating equipment.

Q: Does the valve close if power is lost?
A: Yes, it is normally closed and fails safe on power loss.

Related Products

Honeywell Elster Q and Q75 Quantometer
Honeywell

Honeywell Elster Q and Q75 Quantometer

Honeywell Elster Q and Q75 turbine gas meter for secondary metering.

M7294 Series Damper Actuator
Honeywell

M7294 Series Damper Actuator

M7294 series modulating control damper actuator with spring return.

RM7823A1016/U 7800 Series Flame Relay Module
Honeywell

RM7823A1016/U 7800 Series Flame Relay Module

7800 Series Flame Relay Module