ModelVR8200A2132
Capacity130,000 BTU/h at 1 in. wc drop (20,000-200,000 BTU/h)
ApplicationsUsed in gas-fired standing pilot appliances such as residential furnaces, water heaters and unit heaters with capacities from 30 to 300 cfh.
Key featuresStanding pilot dual automatic valve, single stage, standard opening, 24 V AC 60 Hz.; 1/2 in. x 1/2 in. NPT connections, straight-through body, natural gas with a natural-to-LP conversion kit included.; Capacity rated 130,000 BTU/h at 1 in. wc pressure drop; minimum 20,000 and maximum 200,000 BTU/h natural gas.; Standard pressure regulator with 3.5 in. wc factory setpoint and a 1/2 psi (3.5 kPa) pressure rating.; Solenoid-operated first automatic valve opens on thermostat call for heat; diaphragm-operated second valve closes on loss of gas or power.; Operating temperature 0 to 175 F, mounting 0-90 degrees in any direction, and a 1/8 in. NPT pressure tapping with plug.
Connection size1/2 in. x 1/2 in. NPT
Product categoryResidential combustion component - standing pilot dual automatic combination gas valve
Operating voltage24 V AC, 60 Hz
Regulator setpoint3.5 in. wc