The Honeywell TF832.3 sequences and monitors intermittent oil power burners operating in one or two stages with throughput up to 30 kg/h. Startup begins when the operating switch and twin thermostat close, running the burner motor and ignition spark during pre-purge. After pre-purge, solenoid valve 1 opens to release fuel mist for ignition. When the flame sensor detects combustion, the ignition spark extinguishes two seconds later. If no flame establishes before the safety lockout period expires, the control cuts out and illuminates a red indicator lamp. If an established flame extinguishes during operation, the controller attempts a restart. In the operating position, the burner switches between low and high capacity based on load thermostat demand.